Function |
Code |
Description |
Remark |
Standard Functions |
01 Protection of phase dislocation and phase loss |
3E |
When phase dislocation or phase loss of input power supply occurs, the main circuit and control circuit will be cut off, in order to automatically stop the escalator. |
|
02 Non-operation reversal protection |
ARP |
If reverse movement occurs by accident during operation, the device will cut off the power supply of driving unit and brake. |
|
03 Additional brake |
AUX-BK |
The additional brake system will stop the escalator before that the operating speed is 1.4 times higher than the rated speed, or when the running direction changes. |
When lifting height exceeds 6000mm |
04 Operating brake |
MUSTACHE |
The driving device is equipped with an operating brake. When the operating brake works, the escalator will stop. |
|
05 Safety device of comb plate |
CSS |
If something gets stuck between comb plate and the pedal, the device will cut off the power supply of the driving unit and the brake. |
|
06 Safety device of drive chain |
DCS |
If the drive train breaks or elongates abnormally, the device will cut off the power supply of driving unit and brake. |
|
07 Emergency stop button |
E-STOP |
When an emergency occurs, press the emergency stop button to cut off the power supply of driving unit and brake. |
|
08 Speed limiting device for low speed |
GOV |
If the speed is lower than rated speed by 20%, the device will cut off the power supply of motor and brake. |
|
09 Handrail inlet cover |
HGB |
The long, flexible rubber cover covers at the handrail inlet, to avoid pinching or other accidents. |
|
10 Speed limiting device 1 |
HGD1 |
The device will cut off the power supply of driving unit and brake when the operating speed reaches 1.2 times of the rated speed. |
|
11 Speed limiting device 2 |
HGD2 |
In the operating speed exceeds the rated speed of 1.4 times before, the device operation, and cut off the additional brake power. |
When the lifting height exceeds 6000mm |
12 handrail entry safety device |
HGS |
If a foreign object into the handrail at the entrance card, the device will shut down the drive and the host of the brake power. |
|
13 step chain safety device |
SCS |
If the rung-strand breaks or abnormal elongation, the device will cut off the host drive and brake power. |
|
14 Cascade subsidence safety device |
SRS |
If any part of the rung subsidence damage can not be properly engaged with the upper or lower comb plate, the device will cut off the host drive and brake power. |
|
Optional Functions |
15 signal interface means |
BA |
This output means escalator basic operational status signal. |
When the Model KS-LB, KS-SB, KS-B can only choose one time |
16 Elevator Monitoring System |
SMOS-II |
The system uses state of the computer operation and fault monitoring of the escalator or walkway |
17 skirting safety device |
SSS |
When a foreign body is sandwiched between steps and skirting, the device will shut down the drive and the host of the brake power. |
|